{"id":14115,"date":"2021-05-04T12:36:05","date_gmt":"2021-05-04T10:36:05","guid":{"rendered":"https:\/\/www.schiedel.com\/cz\/?page_id=14115"},"modified":"2022-03-30T13:57:54","modified_gmt":"2022-03-30T11:57:54","slug":"kombiair","status":"publish","type":"page","link":"https:\/\/www.schiedel.com\/cz\/produkty\/ventilacni-systemy\/kombiair\/","title":{"rendered":"KOMBIAIR"},"content":{"rendered":"
Sou\u010d\u00e1st\u00ed nab\u00eddky je zdarma n\u00e1vrh projektov\u00e9 dokumentace, sou\u010d\u00e1st\u00ed dod\u00e1vky jsou v\u0161echny nezbytn\u00e9 komponenty, jejich osazen\u00ed, mont\u00e1\u017e a se\u0159\u00edzen\u00ed do spr\u00e1vn\u00e9ho chodu. V\u0161e kompletn\u011b na kl\u00ed\u010d.<\/strong><\/p>\n Rekupera\u010dn\u00ed jednotky Schiedel jsou osazeny tepeln\u00fdm v\u00fdm\u011bn\u00edkem s \u00fa\u010dinnost\u00ed a\u017e 95%.<\/b>[\/vc_column_text][mk_button_gradient dimension=”flat” size=”medium” corner_style=”rounded” grandient_color_from=”#eec200″ grandient_color_to=”#cca705″ grandient_color_fallback=”#000000″ text_color=”dark” url=”https:\/\/www.schiedel.com\/cz\/produkty\/ventilacni-systemy\/kombiair\/#kontaktni-formular” id_second=”https:\/\/www.schiedel.com\/cz\/produkty\/ventilacni-systemy\/kombiair\/#kontaktni-formular”]NEZ\u00c1VAZN\u011a POPTAT[\/mk_button_gradient][\/vc_column][vc_column width=”1\/2″][mk_image src=”https:\/\/www.schiedel.com\/cz\/wp-content\/uploads\/sites\/17\/2019\/04\/shutterstock_612864071-e1554890369591.jpg” image_size=”full”][\/vc_column][\/vc_row][vc_row id=”proc-vetrat”][vc_column width=”1\/2″][vc_column_text disable_pattern=”false” css=”.vc_custom_1556375630921{margin-bottom: 0px !important;}”]\n<\/a> My ale nev\u00edme p\u0159esn\u011b kdy okno otev\u0159\u00edt, jak dlouho m\u00e1 b\u00fdt otev\u0159en\u00e9 a samoz\u0159ejm\u011b nev\u00edme, kdy ho zav\u0159\u00edt. Nem\u00e1me v sob\u011b m\u011b\u0159i\u010d CO\u2082*, kter\u00fd by n\u00e1s upozornil na znehodnocen\u00fd vzduch. N\u00e1sledkem nedostate\u010dn\u00e9ho v\u011btr\u00e1n\u00ed nap\u0159. v lo\u017enici m\u016f\u017eeme poci\u0165ovat mal\u00e1tnost, nevyspalost a teda nedostate\u010dnou regeneraci organismu sp\u00e1nkem \u2026<\/p>\n Dal\u0161\u00edm probl\u00e9mem je vlhkost. T\u011bsn\u00e1 stavba, dokonal\u00e1 paroz\u00e1brana, zav\u0159en\u00e1 okna, a p\u0159itom\u00a0ka\u017ed\u00fd z n\u00e1s vyprodukuje denn\u011b v dom\u00e1cnosti a\u017e 12 \u2013 15 litr\u016f vlhkosti<\/strong>\u00a0svoj\u00ed p\u0159irozenou \u010dinnost\u00ed (sprchov\u00e1n\u00ed, myt\u00ed, pocen\u00ed, va\u0159en\u00ed, pran\u00ed, su\u0161en\u00ed), to v\u0161e m\u016f\u017ee zp\u016fsobit vlhnut\u00ed st\u011bn a n\u00e1slednou tvorbu pl\u00edsn\u00ed v novostavb\u00e1ch a nejenom v nich.[\/vc_column_text][vc_column_text disable_pattern=”false” css=”.vc_custom_1556379015217{margin-bottom: 0px !important;}”]\n \u010cty\u0159i dobr\u00e9 d\u016fvody pro volbu origin\u00e1ln\u00edch filtr\u016f Zehnder:<\/strong><\/p>\nPro\u010d v\u011btrat<\/h3>\n[\/vc_column_text][vc_column_text disable_pattern=”false” css=”.vc_custom_1620119236443{margin-bottom: 0px !important;}”]Stav\u00edme, nebo\u0165 normy to od n\u00e1s po\u017eaduj\u00ed, a tak\u00e9 my chceme kv\u016fli \u00faspor\u00e1m,\u00a0co nejt\u011bsn\u011bj\u0161\u00ed stavby<\/strong>. Ale zapom\u00edn\u00e1me v\u011btrat. Nebo se spol\u00e9h\u00e1me na p\u0159irozen\u00e9 v\u011btr\u00e1n\u00ed okny.<\/p>\n
V\u011btr\u00e1n\u00ed s rekuperac\u00ed\u00a0<\/strong>Schiedel KombiAir v\u00e1m nab\u00edz\u00ed:<\/strong><\/h4>\n
\n
\nJin\u00fdmi slovy, pokud je ho moc, tak jste mal\u00e1tn\u00ed, nejste odpo\u010dinut\u00ed, m\u00e1te pocit jako byste v\u016fbec nespali. P\u0159itom sta\u010d\u00ed vyv\u011btrat. Ale vstanete v noci, abyste otev\u0159eli okno? Kdy\u017e se v\u00e1m nechce? Nevstanete.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][mk_divider style=”thin_solid” margin_top=”0″][\/vc_column][\/vc_row][vc_row id=”kombiair-zavesne-provedeni”][vc_column][vc_column_text disable_pattern=”false” css=”.vc_custom_1648641470639{margin-bottom: 0px !important;}”]\n<\/a>KOMBIAIR z\u00e1v\u011bsn\u00e9 proveden\u00ed<\/h3>\n[\/vc_column_text][vc_accordions style=”simple-style” container_bg_color=”#ffffff” responsive=”false”][vc_accordion_tab title=”Ucelen\u00fd syst\u00e9m s vysoce hygienick\u00fdmi rozvody”][vc_row_inner][vc_column_inner width=”1\/2″][vc_column_text disable_pattern=”false” css=”.vc_custom_1617883999417{margin-bottom: 0px !important;}”]\n
\n
\n
\n
\n
\n
\n
\n
\n
\n– a\u017e 115.000 K\u010d u rekonstrukce a novostavby po kolaudaci
\n–\u00a0 150-450.000 K\u010d u novostaveb<\/li>\n<\/ul>\n<\/div>\n<\/div>\n[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”Regulace a provoz syst\u00e9mu”][vc_row_inner][vc_column_inner width=”2\/3″][vc_column_text disable_pattern=”false” css=”.vc_custom_1617886167167{margin-bottom: 0px !important;}”]\n\n
\n
\n
Technick\u00e9 \u00fadaje<\/h2>\n[\/vc_column_text][mk_table]\n
\n\n
\n Zehnder portfolio Schiedel<\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/mk_table][mk_table]\n \n\n
\n Jednotka <\/strong><\/td>\n ComfoAir Standard 300<\/strong><\/td>\n ComfoAir standard 375<\/strong><\/td>\n ComfoAir Standard 375 ERV<\/strong><\/td>\n ComfoAir Q350 TR<\/strong><\/td>\n ComfoAir Q350 TR Entalpie<\/strong><\/td>\n ComfoAir Q450 TR<\/strong><\/td>\n ComfoAir Q450 TR Entalpie<\/strong><\/td>\n ComfoAir Q600 TR<\/strong><\/td>\n ComfoAir Q600 TR Entalpie<\/strong><\/td>\n<\/tr>\n \n \u00dadaje dle\u00a0EN 713141-7<\/th>\n<\/tr>\n \n Maxim\u00e1ln\u00ed mo\u017en\u00fd pr\u016ftok vzduchu:<\/strong><\/td>\n 300 m3\/h<\/td>\n 375 m3\/h<\/td>\n 422 m3\/h<\/td>\n 350 m3\/h<\/td>\n 350 m3\/h<\/td>\n 450 m3\/h<\/td>\n 450 m3\/h<\/td>\n 600 m3\/h<\/td>\n 600 m3\/h<\/td>\n<\/tr>\n \n Tepeln\u00e1 \u00fa\u010dinnost (vlhkost):<\/strong><\/td>\n 87%<\/td>\n 86%<\/td>\n 74% (60%)<\/td>\n 93%<\/td>\n 86% (73%)<\/td>\n 93%<\/td>\n 82 % (71%)<\/td>\n 90%<\/td>\n 77% (68%)<\/td>\n<\/tr>\n \n Spot\u0159eba energie (qvd):<\/strong><\/td>\n 93.2 W<\/td>\n 142.3 W<\/td>\n 202 W<\/td>\n 180 W<\/td>\n 180 W<\/td>\n 250 W<\/td>\n 250 W<\/td>\n 350 W<\/td>\n 350 W<\/td>\n<\/tr>\n \n \u0160\u00ed\u0159ka:<\/strong><\/td>\n 625 mm<\/td>\n 725 mm<\/td>\n<\/tr>\n \n \u0160\u00ed\u0159ka v\u010detn\u011b vzduchov\u00fdch hrdel:<\/strong><\/td>\n 702 mm<\/td>\n 790 mm<\/td>\n<\/tr>\n \n V\u00fd\u0161ka:<\/strong><\/td>\n 702 mm<\/td>\n 809 mm<\/td>\n<\/tr>\n \n V\u00fd\u0161ka v\u010detn\u011b vzduchov\u00fdch hrdel:<\/strong><\/td>\n 801 mm<\/td>\n 850 mm<\/td>\n<\/tr>\n \n Hloubka:<\/strong><\/td>\n 572 mm<\/td>\n 570 mm<\/td>\n<\/tr>\n \n Hmotnost:<\/strong><\/td>\n 40 kg<\/td>\n 40 kg<\/td>\n 42 kg<\/td>\n 50 kg<\/td>\n<\/tr>\n \n Hladina akustick\u00e9ho v\u00fdkonu:<\/strong><\/td>\n 40 dB<\/td>\n 40 dB<\/td>\n 40 dB<\/td>\n 41 dB<\/td>\n 41 dB<\/td>\n 45 dB<\/td>\n 45 dB<\/td>\n 51 dB<\/td>\n 51 dB<\/td>\n<\/tr>\n \n Zp\u016fsob p\u0159ipojen\u00ed<\/th>\n<\/tr>\n \n P\u0159ipojen\u00ed vzduchov\u00fdch hrdel:<\/strong><\/td>\n Kruhov\u00e9<\/td>\n<\/tr>\n \n Pr\u016fm\u011br vzduchov\u00fdch hrdel:<\/strong><\/td>\n Vnit\u0159n\u00ed: 160 mm, Vn\u011bj\u0161\u00ed: 180 mm<\/td>\n Vnit\u0159n\u00ed: 160 mm, Vn\u011bj\u0161\u00ed: 180 mm<\/td>\n Vnit\u0159n\u00ed: 160 mm, Vn\u011bj\u0161\u00ed: 180 mm<\/td>\n Vnit\u0159n\u00ed: 160 mm, Vn\u011bj\u0161\u00ed: 180 mm<\/td>\n Vnit\u0159n\u00ed: 160 mm, Vn\u011bj\u0161\u00ed: 180 mm<\/td>\n Vnit\u0159n\u00ed: 160 mm, Vn\u011bj\u0161\u00ed: 180 mm<\/td>\n Vnit\u0159n\u00ed: 160 mm, Vn\u011bj\u0161\u00ed: 180 mm<\/td>\n Vnit\u0159n\u00ed: 180 mm, Vn\u011bj\u0161\u00ed: 200 mm<\/td>\n Vnit\u0159n\u00ed: 180 mm, Vn\u011bj\u0161\u00ed: 200 mm<\/td>\n<\/tr>\n \n Odvod kondenz\u00e1tu:<\/strong><\/td>\n 32 mm \/
\n1 1\/\u2084”<\/td>\n32 mm \/
\n1\u00a01\/\u2084”<\/td>\nNen\u00ed pot\u0159eba \u0159e\u0161it<\/td>\n 32 mm \/
\n1 1\/\u2084”<\/td>\nNen\u00ed pot\u0159eba \u0159e\u0161it<\/td>\n 32 mm \/
\n1 1\/\u2084”<\/td>\nNen\u00ed pot\u0159eba \u0159e\u0161it<\/td>\n 32 mm \/
\n1 1\/\u2084”<\/td>\nNen\u00ed pot\u0159eba \u0159e\u0161it<\/td>\n<\/tr>\n \n P\u0159ipojen\u00ed odvodu kondenz\u00e1tu:<\/strong><\/td>\n Trubka \/ z\u00e1vit<\/td>\n Trubka \/ z\u00e1vit<\/td>\n Trubka \/ z\u00e1vit<\/td>\n Trubka \/ z\u00e1vit<\/td>\n Trubka \/ z\u00e1vit<\/td>\n<\/tr>\n \n Elektrick\u00e1 specifikace<\/th>\n<\/tr>\n \n Maxim\u00e1ln\u00ed spot\u0159eba energie:<\/strong><\/td>\n 230 V \u00b1 10%, 1 f\u00e1ze, 50 Hz<\/td>\n<\/tr>\n \n Jisti\u010d:<\/strong><\/td>\n 10 A<\/td>\n<\/tr>\n \n Materi\u00e1l<\/th>\n<\/tr>\n \n Vn\u011bj\u0161\u00ed:<\/strong><\/td>\n Pota\u017een\u00fd ocelov\u00fdch plech a ABS<\/td>\n<\/tr>\n \n Vnit\u0159n\u00ed:<\/strong><\/td>\n EPP a ABS<\/td>\n<\/tr>\n \n V\u00fdm\u011bn\u00edk tepla:<\/strong><\/td>\n PS<\/td>\n<\/tr>\n \n Entalpick\u00fd v\u00fdm\u011bn\u00edk*:<\/strong><\/td>\n nen\u00ed dostupn\u00fd<\/td>\n nen\u00ed dostupn\u00fd<\/td>\n S-polyether copolymer<\/td>\n nen\u00ed dostupn\u00fd<\/td>\n S-polyether copolymer<\/td>\n nen\u00ed dostupn\u00fd<\/td>\n S-polyether copolymer<\/td>\n nen\u00ed dostupn\u00fd<\/td>\n S-polyether copolymer<\/td>\n<\/tr>\n \n Ostatn\u00ed<\/th>\n<\/tr>\n \n T\u0159\u00edda ochrany:<\/strong><\/td>\n IP 40<\/td>\n<\/tr>\n \n T\u0159\u00edda filtrace:<\/strong><\/td>\n G4 (alternativn\u011b F7)<\/td>\n<\/tr>\n \n By-pass:<\/strong><\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Modula\u010dn\u00ed by-pass<\/td>\n Modula\u010dn\u00ed by-pass<\/td>\n Modula\u010dn\u00ed by-pass<\/td>\n Modula\u010dn\u00ed by-pass<\/td>\n Modula\u010dn\u00ed by-pass<\/td>\n Modula\u010dn\u00ed by-pass<\/td>\n<\/tr>\n \n Mo\u017enost chlazen\u00ed vzduchu:<\/strong><\/td>\n Ne<\/td>\n Ne<\/td>\n Ne<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n<\/tr>\n \n CO2 \u010didlo:<\/strong><\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n<\/tr>\n \n Mobiln\u00ed aplikace ComfoControl:<\/strong><\/td>\n Ne<\/td>\n Ne<\/td>\n Ne<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n<\/tr>\n \n Nad\u0159azen\u00fd
\nsyst\u00e9m KNX:<\/strong><\/td>\nNe<\/td>\n Ne<\/td>\n Ne<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n Ano<\/td>\n<\/tr>\n \n <\/td>\n<\/tr>\n \n * Zaji\u0161t\u011bn\u00ed zdrav\u00e9ho vnit\u0159n\u00edho klima: d\u00edky entalpick\u00e9mu v\u00fdm\u011bn\u00edku, kter\u00fd sni\u017euje riziko p\u0159esu\u0161en\u00ed interi\u00e9ru v zim\u011b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/mk_table][mk_divider style=”thin_solid” margin_top=”0″][vc_column_text disable_pattern=”false” css=”.vc_custom_1617878038130{margin-bottom: 0px !important;}”]\n Skladba syst\u00e9mu<\/h2>\n[\/vc_column_text][vc_row_inner][vc_column_inner width=”1\/2″][mk_image heading_title=”Bungalov” src=”https:\/\/www.schiedel.com\/cz\/wp-content\/uploads\/sites\/17\/2021\/04\/rekuperace-bungalov.jpg” image_size=”full”][\/vc_column_inner][vc_column_inner width=”1\/2″][mk_image heading_title=”Podla\u017en\u00ed rodinn\u00fd d\u016fm” src=”https:\/\/www.schiedel.com\/cz\/wp-content\/uploads\/sites\/17\/2021\/04\/rekuperace-zehnder-schema-podlazniho-domu.jpg” image_size=”full”][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=”1\/2″][vc_column_text disable_pattern=”false” css=”.vc_custom_1617882933789{margin-bottom: 0px !important;}”]1.\u00a0<\/strong>P\u0159\u00edvod \u010derstv\u00e9ho vzduchu do domu
\n2.\u00a0<\/strong>P\u0159\u00edvodn\u00ed potrub\u00ed venkovn\u00edho vzduchu
\n3.\u00a0<\/strong>Rekupera\u010dn\u00ed jednotka
\n4.\u00a0<\/strong>Akustick\u00fd tlumi\u010d s rozd\u011blova\u010dem
\n5.\u00a0<\/strong>V\u011btrac\u00ed trubky pro hygienick\u00fd rozvod vzduchu
\n6.\u00a0<\/strong>V\u011btrac\u00ed trubky pro odvod znehodnocen\u00e9ho vzduchu
\n7.\u00a0<\/strong>V\u00fdfukov\u00e1 d\u00fdza
\n8.\u00a0<\/strong>Odvod znehodnocen\u00e9ho vzduchu vn\u011b objektu[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/2″][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row id=”ke-stazeni”][vc_column][vc_column_text disable_pattern=”false”]\n<\/a>Ke sta\u017een\u00ed<\/h3>\n[\/vc_column_text][vc_column_text disable_pattern=”false” css=”.vc_custom_1554887873101{margin-bottom: 0px !important;}”]