{"id":6146,"date":"2016-11-09T14:43:33","date_gmt":"2016-11-09T13:43:33","guid":{"rendered":"https:\/\/www.schiedel.com\/sk\/?page_id=6146"},"modified":"2023-10-03T12:00:41","modified_gmt":"2023-10-03T10:00:41","slug":"faq-najcastejsie-kladene-otazky","status":"publish","type":"page","link":"https:\/\/www.schiedel.com\/sk\/servis\/faq-najcastejsie-kladene-otazky\/","title":{"rendered":"FAQ – Naj\u010dastej\u0161ie kladen\u00e9 ot\u00e1zky"},"content":{"rendered":"
[mk_page_section min_height=”50″ padding_top=”5″ sidebar=”sidebar-1″][vc_column width=”1\/2″][vc_column_text]\n

Naj\u010dastej\u0161ie kladen\u00e9 ot\u00e1zky<\/h2>\n[\/vc_column_text][vc_column_text]\n

F.A.Q.<\/h1>\n[\/vc_column_text][vc_column_text css=”.vc_custom_1509444923825{margin-bottom: 0px !important;}”]Tu sa V\u00e1m pok\u00fasime zodpoveda\u0165 tie naj\u010dastej\u0161ie kladen\u00e9 ot\u00e1zky od z\u00e1kazn\u00edkov.<\/p>\n

Sk\u00faste si n\u00e1js\u0165 pr\u00e1ve t\u00fa Va\u0161u ot\u00e1zku, ktor\u00fa by ste n\u00e1m radi polo\u017eili.<\/p>\n

Ak nen\u00e1jdete, nev\u00e1hajte n\u00e1s kontaktova\u0165, telefonicky<\/a> alebo mailom<\/a>.
\nNa\u0161ou \u00falohou je V\u00e1m pom\u00f4c\u0165 k vo\u013ebe toho spr\u00e1vneho rie\u0161enia.[\/vc_column_text][\/vc_column][vc_column width=”1\/2″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2016\/05\/csm_Schiedel-Systemhaus_65f2b21ec2.jpg” image_size=”full”][\/vc_column][\/mk_page_section][vc_row][vc_column][vc_accordions style=”simple-style” container_bg_color=”#ffffff”][vc_accordion_tab title=”A. Akcia na kom\u00edny”][vc_column_text css=”.vc_custom_1629791805743{margin-bottom: 0px !important;}”]V pr\u00edpade, \u017ee chcete vyu\u017ei\u0165 na\u0161u aktu\u00e1lnu akciu na k\u00fapu kom\u00ednov\u00fdch telies Schiedel ,
kliknite sem,<\/a> vyp\u00ed\u0161te formul\u00e1r a na\u0161i pracovn\u00edci V\u00e1m spracuj\u00fa cenov\u00fa ponuku pod\u013ea Va\u0161ich predst\u00e1v. A nie, Schiedel na krb nestoj\u00ed 2000 \u20ac. \ud83d\ude09<\/p>\n

Pr\u00edpadne si n\u00e1s lajknite na facebooku<\/a> alebo instagrame<\/a>, a u\u017e ni\u010d zauj\u00edmav\u00e9 ku kom\u00ednom v\u00e1m neujde.[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab title=”1. Pre\u010do kom\u00edn Schiedel?”][vc_row_inner][vc_column_inner width=”2\/3″][vc_column_text css=”.vc_custom_1629791687343{margin-bottom: 0px !important;}”]Ak m\u00e1 stavba spr\u00e1vny kom\u00edn<\/strong>, je pripraven\u00e1 na zabezpe\u010denie tepelnej pohody, nez\u00e1vislosti
\na
so spr\u00e1vnym kom\u00ednov\u00fdm syst\u00e9mom<\/a> je aj bezpe\u010dnou stavbou.<\/p>\n

Kom\u00edn napojen\u00fd na piecku, krb, kachle V\u00e1m v\u017edy zabezpe\u010d\u00ed pr\u00edjemn\u00e9 teplo.<\/p>\n

Teda budete ma\u0165 teplo a svetlo za ka\u017ed\u00fdch okolnost\u00ed<\/strong>.<\/p>\n

Dom by mal ma\u0165 aspo\u0148 jeden kom\u00edn<\/a>.<\/p>\n

Pre\u010do Schiedel?<\/strong><\/h6>\n

Kvalita<\/strong> overen\u00e1 75 rokmi<\/p>\n

Vlastn\u00e1 v\u00fdroba<\/strong> komponentov, ten najd\u00f4le\u017eitej\u0161\u00ed, keramick\u00e9 vlo\u017eky, si Schiedel vyr\u00e1ba s\u00e1m<\/p>\n

Jedine\u010dn\u00fd servis<\/strong> – online chat, technici a odborn\u00ed poradcovia v ka\u017edom regi\u00f3ne Slovenska<\/strong><\/p>\n

– Mili\u00f3ny z\u00e1kazn\u00edkov v Eur\u00f3pe, desiatky tis\u00edcov kom\u00ednov Schiedel na Slovensku<\/p>\n

– \u0160irok\u00e1 paleta syst\u00e9mov, priemerov[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2019\/04\/schiedel-logo-2019-print-pdf-image.jpg” image_size=”full”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”2. Prv\u00e1 a z\u00e1kladn\u00e1 chyba”][vc_row_inner][vc_column_inner width=”2\/3″][vc_column_text css=”.vc_custom_1629785958101{margin-bottom: 0px !important;}”]\u0160etri\u0165 na kom\u00edne*.<\/p>\n

Staviate dom, ktor\u00fd u\u017e dnes mus\u00ed sp\u013a\u0148a\u0165 \u0161tandardy NED<\/strong> alebo dokonca staviate pas\u00edvny dom. Jednoducho povedan\u00e9, staviate \u010do najkvalitnej\u0161ie<\/strong> (s kom\u00ednom Schiedel ABSOLUT)<\/a>, aby ste mali \u010do najmen\u0161ie n\u00e1klady<\/strong> na vykurovanie.<\/p>\n

400 mm m\u00fary, 7-komorov\u00e9 okn\u00e1 s trojit\u00fdm zasklen\u00edm , aspo\u0148 100 mm izol\u00e1cie na obvodovej stene.<\/p>\n

A potom pou\u017eijete kom\u00edn s mrie\u017ekou v jeho p\u00e4te. T\u00e1 mrie\u017eka prep\u00e1ja interi\u00e9r s exteri\u00e9rom a je to miesto tepeln\u00fdch str\u00e1t. Zadn\u00e9 odvetranie kom\u00edna, kv\u00f4li tomu tam t\u00e1 mrie\u017eka je, dok\u00e1\u017ee odvies\u0165 25 m3 vzduchu, ktor\u00fd ste zohriali, ktor\u00e9ho zohriatie ste zaplatili.<\/p>\n

E\u0161te hor\u0161ie je, ak investujete do rekuper\u00e1cie a tento otvor v p\u00e4te kom\u00edna jej \u010dinnos\u0165 absol\u00fatne znehodnot\u00ed.<\/p>\n

Op\u00fdtajte sa n\u00e1s<\/a>, ako pred\u00eds\u0165 strat\u00e1m, probl\u00e9mom, mrhaniu s Va\u0161imi prostriedkami.<\/strong> Na\u0161i pracovn\u00edci<\/a> V\u00e1m radi poradia a pom\u00f4\u017eu. My sme \u0161pecialisti na kom\u00edny. Schiedel u\u017e 75 rokov a na Slovensku od 1994.<\/p>\n

 <\/p>\n

*Hladime na tesnost stavby, tesne mury, tesne vyplne otvorov, 8-komorove okna, 3-jite zasklenie, inspirujeme sa laikami na modrejstreche kto co ako urobil lepsie, tesnejsie , kvalitnejsie, odbavujeme sa na tom ze platime o 5 az 50 \u20ac menej na kureni ako sused, kontrolujeme kvalitu stavby blower-door testom, behame po dome a kontrolujeme ramy okien,zasuvky s anemometrom na prienik vzduchu cez tie male dierky, prelepujeme kazdu dierku v parozabrane. Kupujeme rekuperaciu, lebo sme postavili tesny dom a chceme predsa dychat , zregulujeme ju, vytesujeme sa aku sme si kupili \u00a0s akou uzasnou ucinnostou a potom to zabijeme kominom s dierou v pate. 17*19 cm. Dierou, ktora priamo prepaja interier s exterierom. Rekuperacia pracuje v rovnovaznom stave, teda +\/- par percent rozdielu. Ak je rekuperacia podtlakova a nasaje spaliny cez zadne odvetranie…. To nechcete. Je potom otvor v pate komina privod alebo odvod? Potom s akou ucinnostou ta rekuperacia pracuje? Nakolko plni svoj ucel?[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/08\/schema-absolut-2.jpg” image_size=”full”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”3. \u010co tr\u00e1pi mysliaceho krb\u00e1ra? Za v\u00e1s. Alebo 8 krokov pre \u0161\u0165astn\u00fd a pokojn\u00fd sp\u00e1nok v\u00e1s a krb\u00e1ra.”][vc_row_inner][vc_column_inner width=”2\/3″][vc_column_text css=”.vc_custom_1526557925738{margin-bottom: 0px !important;}”]\n

    \n
  1. Odvod vlhkosti v\u00a0p\u00e4te kom\u00edna<\/strong>. Vlhkos\u0165ou, ktor\u00e1 n\u00e1s tr\u00e1pi je poveternostn\u00e1 vlhkos\u0165, ktor\u00e1 sa dostane do prieduchu. Aj ke\u010f d\u00e1te strie\u0161ku nad kom\u00edn, vlhkos\u0165 sa do kom\u00edna dostane. \u010eal\u0161\u00edm typom je vlhkos\u0165 vyzr\u00e1\u017ean\u00e1 z\u00a0vlhkosti obsiahnutej vo forme pary v\u00a0spalin\u00e1ch (z dreva, vzduchu na horenie …). Nezabudnite preto naprojektova\u0165 kanaliz\u00e1ciu ku kom\u00ednu, alebo pod kom\u00edn, 40 mm sta\u010d\u00ed. Do nej priamo napoj\u00edte odvod z\u00a0kom\u00edna, teda ak ju nezabudnete zrealizova\u0165.<\/li>\n
  2. Zle vyrie\u0161en\u00e9 odvetranie<\/strong>. Mrie\u017eka v\u00a0p\u00e4te kom\u00edna tam bu\u010f nie je, alebo je utopen\u00e1 v\u00a0podlahe. M\u00e1 by\u0165 nad \u010distou podlahou a\u00a0do interi\u00e9ru. Nenap\u00e1jajte zadn\u00e9 odvetranie kom\u00edna z\u00a0exteri\u00e9ru. Potom kom\u00edn ne\u0165ah\u00e1, lebo ho ochladzujete a\u00a0ke\u010f ne\u0165ah\u00e1 kom\u00edn, nefunguje krb ako m\u00e1 a\u00a0sklo b\u00fdva \u010dierne.<\/li>\n
  3. Dopojenie v\u00a0bl\u00edzkosti hor\u013eav\u00fdch materi\u00e1lov<\/strong>. Je probl\u00e9mom ke\u010f nie je dodr\u017ean\u00e1 bezpe\u010dn\u00e1 vzdialenos\u0165 od hor\u013eav\u00fdch \u010dast\u00ed stavby. Pri jednopl\u00e1\u0161\u0165ovom dymovode to m\u00f4\u017ee by\u0165 a\u017e 400 mm. Konzultujte preto realiz\u00e1ciu v\u00a0bl\u00edzkosti hor\u013eav\u00fdch materi\u00e1lov e\u0161te pred samotn\u00fdm n\u00e1vrhom. Rie\u0161te krb s\u00a0krb\u00e1rom, tak ako kuchynsk\u00fa linku, u\u017e vo f\u00e1ze n\u00e1vrhu drevodomu \ud83d\ude09<\/li>\n
  4. Bezpe\u010dn\u00fd odstup kom\u00edna<\/strong>. Bezpe\u010dn\u00e9 odstupov\u00e9 vzdialenosti m\u00e1 ka\u017ed\u00fd v\u00fdrobca kom\u00edna in\u00e9. S\u00fa dan\u00e9 vlastnos\u0165ami kon\u0161trukcie kom\u00edna ale to podstatn\u00e9 sa odohr\u00e1va na stavbe. Teda sp\u00f4sob zabudovania ur\u010duje odstupov\u00e9 vzdialenosti. Seri\u00f3zna firma = seri\u00f3zne a\u00a0presn\u00e9 inform\u00e1cie. Nedodr\u017eanie podmienok ohrozuje stavbu a\u00a0va\u0161e zdravie.<\/li>\n
  5. Z\u00e1klad pod kom\u00ednom<\/strong>. Navrhn\u00fa\u0165 ho je povinnos\u0165ou projektanta, zrealizova\u0165 va\u0161ou alebo stavebnej firmy. H\u013abka z\u00e1kladu a\u00a0jeho plocha z\u00e1vis\u00ed od nez\u00e1mrznej h\u013abky, \u00fanosnosti zeminy a\u00a0hmotnosti kom\u00edna. Pri rodinnom dome po\u010d\u00edtajte s\u00a0hmotnos\u0165ou od 100 kg na 1 meter kom\u00edna. Tak\u017ee z\u00e1klad mus\u00ed by\u0165 minim\u00e1lne v\u00a0podobe dvojn\u00e1sobnej rozn\u00e1\u0161acej v\u00fdstu\u017ee s\u00a0okom minim\u00e1lne 150\/150mm a\u00a06 mm dr\u00f4tom v\u00a0z\u00e1kladovej doske z\u00a0B20 v\u00a0hr\u00fabke min. 200 mm. +\/-<\/li>\n
  6. Povrchov\u00e1 teplota kom\u00edna<\/strong>. Oce\u013eov\u00fd kom\u00edn z\u00a0nehrdzavej\u00facej ocele m\u00f4\u017ee dosiahnu\u0165 na povrchu pri k\u00faren\u00ed v\u00a0krbovej vlo\u017eke bez probl\u00e9mov 150\u00b0C. To nie je na bezpe\u010dn\u00fd dotyk. Preto spravte kom\u00edn \u010do najmenej pr\u00edstupn\u00fd. Pozera\u0165 sa m\u00f4\u017eete, dot\u00fdka\u0165 neodpor\u00fa\u010dame.<\/li>\n
  7. Paroz\u00e1brana m\u00e1 by\u0165 bezpe\u010dn\u00e1 a\u00a0tesn\u00e1 pri kom\u00edne.<\/strong> A\u00a0preto by mala by\u0165 po celej ploche stropu. Aj okolo kom\u00edna. Ak m\u00e1te kom\u00edn z\u00a0bet\u00f3nov\u00fdch tv\u00e1rnic, napr. Schiedel ABSOLUT, m\u00f4\u017eete napoji\u0165 f\u00f3liu priamo na prechodov\u00fa tv\u00e1rnicu (tzv. thermotrennstein), alebo na vrstvu zateplenia, ak m\u00e1te in\u00fd typ kom\u00edna. Pri kovov\u00fdch kom\u00ednoch mus\u00edte pre tesnos\u0165 stavby urobi\u0165 ur\u010dite viac. Pou\u017ei\u0165 prechodov\u00fd komponent VPC alebo VermiS. Oboje od fy Schiedel. Takto nebude kom\u00edn miestom \u00faniku tepla a\u00a0miestom vzniku po\u017eiaru.<\/li>\n
  8. Statick\u00e9 zabezpe\u010denie kom\u00edna.<\/strong> B\u00fdva Achillovou p\u00e4tou kom\u00edna. Kom\u00edn mus\u00ed by\u0165 v\u00a0rovine strechy staticky zabezpe\u010den\u00fd proti p\u00e1du pod vplyvom vetra. To znamen\u00e1 ho bezpe\u010dn\u00fdm a\u00a0overen\u00fdm sp\u00f4sobom fixova\u0165 medzi krokvami. Nie drevom (li\u0161tami, krokvami, kusmi dreva), nie mont\u00e1\u017enou penou. D\u00f4verujte len overen\u00fdm rie\u0161eniam od overen\u00fdch v\u00fdrobcov. Pozv\u00e1ra\u0165 uholn\u00edky a\u00a0ty\u010de dok\u00e1\u017ee skoro ka\u017ed\u00fd, ale garantova\u0165 statick\u00fa bezpe\u010dnos\u0165 len m\u00e1lokto.<\/li>\n<\/ol>\n[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/08\/1-1.png” image_size=”full”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”4. Ako vysoko m\u00e1 by\u0165 kom\u00edn nad strechou?”][vc_row_inner][vc_column_inner width=”1\/2″][vc_column_text]V\u00fd\u0161ku kom\u00edna nad strechou ur\u010dil V\u00e1\u0161 zodpovedn\u00fd projektant<\/strong> vo Va\u0161om projekte.<\/p>\n

    Jeho spr\u00e1vnos\u0165 n\u00e1vrhu si m\u00f4\u017eete overi\u0165 \u00a0v STN EN 15287-1<\/strong> . Alebo priamo u n\u00e1s na technickom oddelen\u00ed alebo prostredn\u00edctvom na\u0161ich odborn\u00fdch poradcov. Priklad\u00e1me viacer\u00e9 mo\u017enosti v\u00fd\u0161ok kom\u00edna nad strechou. Ktor\u00fa mo\u017enos\u0165 si zvol\u00edte, z\u00e1vis\u00ed od vzdialenosti kom\u00edna od hrebe\u0148a, miestnych podmienok – teda prevl\u00e1daj\u00faci smer vetrov, alebo od typu suseda, na druhej strane V\u00e1\u0161ho , jeho, plota. :-)[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/2″][mk_image heading_title=”Pre \u0161ikm\u00e9 strechy, so sklonom vy\u0161\u0161\u00edm ako 20\u00b0 plat\u00ed:” src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2023\/10\/schiedel-vyska-komina-nad-strechou-sikma-strecha.png” image_size=”full”][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=”1\/2″][mk_image heading_title=”V\u00fd\u0161ka kom\u00edna na tuh\u00e9 palivo nad plochou strechou, teda so sklonom ni\u017e\u0161\u00edm ako 20\u00b0” src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2023\/10\/grafika-strechy-1-1.png” image_size=”full”][\/vc_column_inner][vc_column_inner width=”1\/2″][vc_column_text css=”.vc_custom_1695881272553{margin-bottom: 0px !important;}”]V\u00fd\u0161ka kom\u00edna vzh\u013eadom k okraju strechy sa riadi bu\u010f pod\u013ea atiky alebo samotnej plochy strechy. Ak je atika, tak v\u00fd\u0161ku kom\u00edna vz\u0165ahujeme k danej atike. V\u017edy v\u0161ak plat\u00ed, \u017ee v\u00fd\u0161ka vy\u00fastenia spal\u00edn mus\u00ed by\u0165 minim\u00e1lne 4 m nad ter\u00e9nom pre plynn\u00e9 paliv\u00e1 a 6 m pre tuh\u00e9 paliv\u00e1 (Vyhl. 248\/2023 M\u017dP SR)!<\/strong>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=”1\/2″][vc_column_text css=”.vc_custom_1622120902869{margin-bottom: 0px !important;}”]\n

    Pred samotnou k\u00fapou kotla si preverte ak\u00e9 m\u00e1 po\u017eiadavky na \u0165ah v kom\u00edne. Ani tak kvalitn\u00fd kom\u00edn ako Schiedel nedok\u00e1\u017ee pri svojej celkovej v\u00fd\u0161ke 6,5 m (be\u017en\u00e1 v\u00fd\u0161ka kom\u00edna pri jednopodla\u017en\u00fdch budov\u00e1ch typu bungalov) vyvin\u00fa\u0165 v\u00fdrobcom kotla po\u017eadovan\u00fd \u0165ah 23 – 30 Pa.
    \nAby kom\u00edn vyvinul tak\u00fd \u0165ah mus\u00ed ma\u0165 v\u00fd\u0161ku 10-12 m. Preto v\u00fdbere kotla h\u013eadajte tak\u00fd kotol, aby mal potrebu \u0165ahu v rozsahu 4 a\u017e 12 Pa.
    \nRadi over\u00edme bezplatne v\u00fdpo\u010dtom majite\u013eom kom\u00edna Schiedel vhodnos\u0165 kotla pre ich kom\u00edn, jeho v\u00fd\u0161ku a priemer.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/2″][mk_image heading_title=”Probl\u00e9m s kotlom a n\u00e1sledne s kom\u00ednom pri n\u00edzkej v\u00fdstavbe” src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/05\/grafika-strechy-3.png” image_size=”full”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”5. M\u00f4\u017eem ma\u0165 jeden prieduch na plyn aj tuh\u00e9 palivo?”][vc_row_inner][vc_column_inner width=”2\/3″][vc_column_text]Nem\u00f4\u017eete kombinova\u0165 typy paliva v jednom kom\u00ednovom prieduchu. Preto pre plynov\u00fd kotol mus\u00edte ma\u0165 samostatn\u00fd prieduch a pre tuh\u00e9 paliv\u00e1 (krb, piecka, kachle) \u010fal\u0161\u00ed samostatn\u00fd prieduch<\/strong>. Ide\u00e1lnou vo\u013ebou m\u00f4\u017ee by\u0165 napr\u00edklad kom\u00ednov\u00fd syst\u00e9m
    Schiedel KOMBIGAS<\/a>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2016\/07\/kombigas_brusena_tvarnica_gasfix_solar-2.jpg” image_size=”News Image Small” svg=”true” align=”right”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”6. Ko\u013eko prieduchov m\u00e1 ma\u0165 kom\u00edn?”][vc_row_inner][vc_column_inner width=”1\/3″][vc_column_text]Odpor\u00fa\u010dame ma\u0165 dva prieduchy alebo dva kom\u00edny.<\/p>\n

    V dne\u0161nej dobe V\u00e1m povedia “radcovia” \u017ee ve\u010f na plynov\u00fd kondenza\u010dn\u00fd kotol ti sta\u010d\u00ed len v\u00fdfuk, nepotrebuje\u0161 kom\u00edn (uk\u00e1\u017eka \u010do dok\u00e1\u017ee v\u00fdfuk urobi\u0165 s Va\u0161ou strechou)<\/a>. Ak chcete zosta\u0165 nav\u017edy z\u00e1visl\u00ed<\/strong> len na plyne, tak je \u017eia\u013e tak\u00e9 rie\u0161enie. Ak teraz zvol\u00edte variantu napojenia kotla (aj turbokotla) na spr\u00e1vny kom\u00edn, m\u00f4\u017eete kedyko\u013evek v bud\u00facnosti po\u010das celej \u017eivotnosti stavby a kom\u00edna zmeni\u0165 palivo<\/strong>. Napr\u00edklad pou\u017ei\u0165 kotol na peletky. Vsypete 15 kg vrece a t\u00fd\u017ede\u0148 prev\u00e1dzky m\u00e1te ist\u00fd. S plastovou r\u00farou na plynovom kotli tak\u00fa mo\u017enos\u0165 nem\u00e1te. \u00a0Navy\u0161e , kom\u00edn mus\u00ed by\u0165 vy\u00fasten\u00fd nad strechou vy\u0161\u0161ie a teda od spal\u00edn z kom\u00edna zostane Va\u0161a strecha nepo\u0161koden\u00e1. Vi\u010f. vy\u00fastenia plynov\u00fdch kotlov v\u00fdfukom…<\/a>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”2\/3″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/08\/bild_haus_3d.png” image_size=”full”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”7. Ak\u00fd priemer kom\u00edna potrebujem na krb, piecku, kotol?”][vc_row_inner][vc_column_inner][vc_column_text]Na piecku V\u00e1m sta\u010d\u00ed 160 mm. Na kotol na tuh\u00e9 palivo m\u00f4\u017ee by\u0165 180, na krbov\u00fa vlo\u017eku 200 mm. To je jednoduch\u00e1 odpove\u010f a aj ve\u013emi \u010dasto pou\u017e\u00edvan\u00e1 r\u00f4znymi “odborn\u00edkmi”.<\/p>\n

    My v Schiedli si vypo\u010dujeme va\u0161e predstavy, pop\u00fdtame sa V\u00e1s na typ, v\u00fdkon spotrebi\u010da, v\u00fd\u0161ku kom\u00edna, kde staviate (nadm.v\u00fd\u0161ku) a odporu\u010d\u00edme V\u00e1m ten spr\u00e1vny priemer. My V\u00e1s upozorn\u00edme, \u017ee ke\u010f m\u00e1te bungalov, a teda n\u00edzky kom\u00edn, \u017ee v\u00fdber spotrebi\u010da bude nesmierne d\u00f4le\u017eit\u00fd. Odporu\u010d\u00edme V\u00e1m spotrebi\u010d s \u010do najmen\u0161ou potrebou \u0165ahu.<\/p>\n

    Nem\u00f4\u017eete o\u010dak\u00e1va\u0165, \u017ee pri celkovej v\u00fd\u0161ke kom\u00edna 6,3 metra bude ma\u0165 kom\u00edn \u0165ah, po\u017eadovan\u00fd lacn\u00fdm drevosply\u0148uj\u00facim kotlom, 25-30 Pa. Tak\u00fdto spotrebi\u010d V\u00e1m sp\u00f4sob\u00ed len probl\u00e9my. Ani kom\u00edn nebude ma\u0165 dostato\u010dn\u00fd \u0165ah.<\/p>\n

    Spracujeme V\u00e1m v\u00fdpo\u010det, na\u0161i odborn\u00ed pracovn\u00edci V\u00e1m ten spr\u00e1vny priemer poradia bezplatne. V ka\u017edom z krajov Slovenska m\u00e1me odborn\u00fdch poradcov.<\/strong>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=”1\/4″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/05\/spravcanetu-ms-48-muv-abx_page_1.png” image_size=”full”][\/vc_column_inner][vc_column_inner width=”1\/4″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/05\/spravcanetu-ms-48-muv-abx_page_2.png” image_size=”full”][\/vc_column_inner][vc_column_inner width=”1\/4″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/05\/spravcanetu-ms-48-muv-abx_page_3.png” image_size=”full”][\/vc_column_inner][vc_column_inner width=”1\/4″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/05\/spravcanetu-ms-48-muv-abx_page_4.png” image_size=”full”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”8. M\u00f4\u017eem ma\u0165 na jeden kom\u00edn pripojen\u00e9 dva krby, piecky?”][vc_row_inner][vc_column_inner][vc_column_text]Aktu\u00e1lna legislat\u00edva (401\/2007) prip\u00fa\u0161\u0165a t\u00fato mo\u017enos\u0165 pod podmienkou, \u017ee v\u00fdrobca spotrebi\u010da t\u00fato mo\u017enos\u0165 v podkladoch ku spotrebi\u010du vyslovene deklaruje.
    \nPredpokladom b\u00fdva, \u017ee sa jedn\u00e1 o tesn\u00fd spotrebi\u010d, vzduch na horenie je priv\u00e1dzan\u00fd z exteri\u00e9ru priamo do spotrebi\u010da pod\u013ea po\u017eiadaviek v\u00fdrobcu spotrebi\u010da (teda \u017eiadne nas\u00e1vanie z priestoru, kde sa spotrebi\u010d nach\u00e1dza).<\/p>\n

    Ak je pou\u017eit\u00fd nespr\u00e1vny spotrebi\u010d alebo dokonca kombin\u00e1cia viacer\u00fdch druhov, vystavujete sa nebezpe\u010denstvu otravy. Pri nespr\u00e1vnom pr\u00faden\u00ed spal\u00edn (vietor tla\u010d\u00ed spaliny sp\u00e4\u0165 do prieduchu), netesnom spotrebi\u010di doch\u00e1dza pri nespr\u00e1vnom horen\u00ed k tvorbe oxidu uho\u013enat\u00e9ho . Vy budete c\u00edti\u0165 spaliny, ale oxid uho\u013enat\u00fd (CO) je plyn bez z\u00e1pachu, av\u0161ak spo\u013eahlivo a r\u00fdchlo zab\u00edjaj\u00faci. Na opustenie miestnosti pred stratou vedomia m\u00e1te p\u00e1r sek\u00fand….<\/p>\n

    Preto je na\u0161e odpor\u00fa\u010danie jednozna\u010dn\u00e9. \u010co spotrebi\u010d, to samostatn\u00fd kom\u00ednov\u00fd prieduch<\/strong>. Cena \u017eivota je viac ako cena kom\u00edna.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”9. Ako vysoko urobi\u0165 napojenie na kom\u00edn?”][vc_column_text css=”.vc_custom_1517491979870{margin-bottom: 0px !important;}”]Na piecku urobte napojenie vo v\u00fd\u0161ke 1,6-1,8 m.
    \nNa krbov\u00e9 teleso 1,8-2,0 m od \u010distej podlahy.
    \nNa plynov\u00fd kotol 2,1-2,3m.<\/p>\n

    Odpor\u00fa\u010dan\u00e9 v\u00fd\u0161ky s\u00fa myslen\u00e9 od \u010distej podlahy!
    \nNezabudnite na pr\u00edvod vzduchu na horenie \u0161achtou kom\u00edna, alebo v kon\u0161trukcii podlahy. Sp\u00f4sob pr\u00edvodu vzduchu z\u00e1vis\u00ed od typu spotrebi\u010da.[\/vc_column_text][vc_column_text css=”.vc_custom_1637062897410{margin-bottom: 0px !important;}”]V\u00fd\u0161ky k\u00f3tovan\u00e9 na spodnom obr\u00e1zku s\u00fa od spodnej hrany prvej tv\u00e1rnice!
    \n<\/strong><\/p>\n

    Teda v pr\u00edpade kom\u00edna so zadn\u00fdm odvetran\u00edm (mrie\u017eka v p\u00e4te kom\u00edna) mus\u00edte pod kom\u00ednom vytvori\u0165 z\u00e1klad tak, aby mrie\u017eka bola nad \u00farov\u0148ou \u010distej podlahy pre zabezpe\u010denie funkcionality zadn\u00e9ho odvetrania<\/p>\n

    *Pri syst\u00e9me UNI Advanced je dan\u00e1 v\u00fd\u0161ka v pr\u00edpade pou\u017eitia prefabrikovanej kom\u00ednovej p\u00e4ty (810 mm – p\u00e4ta stavan\u00e1 na mieste, 855 mm pri pou\u017eit\u00ed prefabrikovanej p\u00e4ty).<\/p>\n

    \"\"[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab title=”10. Pre\u010do ma\u0165 kom\u00edn aj na plynov\u00fd kondenza\u010dn\u00fd kotol, ke\u010f mi hovoria, \u017ee mi ho netreba?”][vc_row_inner][vc_column_inner width=”2\/3″][vc_column_text]Kom\u00edn \u00a0na plynov\u00fd kondenza\u010dn\u00fd kotol je lep\u0161\u00edm rie\u0161en\u00edm.<\/strong><\/p>\n

    Spaliny z kondenza\u010dn\u00e9ho kotla , ktor\u00fd je vy\u00fasten\u00fd len plastov\u00fdm v\u00fdfukom, okam\u017eite po vyf\u00faknut\u00ed skondenzuj\u00fa<\/strong>, kondenz\u00e1t spadne na stre\u0161n\u00fa krytinu a ke\u010f\u017ee je kondenz\u00e1t v podstate kyselina, tak doch\u00e1dza k po\u0161kodzovaniu stre\u0161nej krytiny<\/strong>. Ako tak\u00e9 po\u0161kodenie vyzer\u00e1? Takto!<\/a><\/p>\n

    Kom\u00ednov\u00e9 teleso, t\u00fdm, \u017ee je vy\u0161\u0161ie nad strechou umo\u017en\u00ed v\u00fdrazne lep\u0161ie rozpt\u00fdlenie spal\u00edn. Naviac, pri spr\u00e1vnej vo\u013ebe kom\u00edna, m\u00f4\u017ee bez dodato\u010dn\u00e9ho vlo\u017ekovania priv\u00e1dza\u0165 aj vzduch ku kotlu. Kom\u00edny Schiedel nemus\u00edte vlo\u017ekova\u0165<\/strong>, aby ste pripojili plynov\u00fd kondenza\u010dn\u00fd kotol. Op\u00fdtajte sa n\u00e1s ako u\u0161etri\u0165<\/a> a zbyto\u010dne neplati\u0165 k\u00faren\u00e1rovi, in\u0161talat\u00e9rovi<\/strong>, za nie\u010do, \u010do nepotrebujete.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2016\/11\/kondenzacny-kotol-turbo-7.png” image_size=”full”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”11. Ak\u00fd kom\u00edn do NED alebo PD?”][vc_row_inner][vc_column_inner width=”2\/3″][vc_column_text css=”.vc_custom_1629810936035{margin-bottom: 0px !important;}”]Je ve\u013emi d\u00f4le\u017eit\u00e9 zvoli\u0165 ten spr\u00e1vny kom\u00ednov\u00fd syst\u00e9m<\/strong> do NED alebo PD. V oboch pr\u00edpadoch sa sna\u017e\u00ed investor stava\u0165 \u010do najtesnej\u0161ie, aby minimalizoval tepeln\u00e9 straty. Preto by mal \u00eds\u0165 do oboch typov stavieb kom\u00edn, ktor\u00fd nem\u00e1 zadn\u00e9 odvetranie, teda mrie\u017eku v p\u00e4te kom\u00edna. Tou mrie\u017ekou V\u00e1m pr\u00fadi zaplaten\u00fd tepl\u00fd vzduch do exteri\u00e9ru. Takisto uveden\u00e1 mrie\u017eka v p\u00e4te kom\u00edna bude miestom, kde d\u00f4jde k znehodnoteniu Va\u0161ej invest\u00edcie do rekuper\u00e1cie.<\/p>\n

    Preto si nechajte poradi\u0165 <\/a>a vo\u013ete jedin\u00fd syst\u00e9m na slovenskom trhu s integrovanou nenasiakavou izol\u00e1ciou a bez zadn\u00e9ho odvetrania. Schiedel ABSOLUT<\/a>.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/08\/schema-absolut-2.jpg” image_size=”full”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”12. Urobi\u0165 napojenie 90\u00b0alebo 45\u00b0?”][vc_row_inner][vc_column_inner width=”1\/2″][vc_column_text css=”.vc_custom_1629812818836{margin-bottom: 0px !important;}”]45\u00b0 napojenie odpor\u00fa\u010dame na tuh\u00e9 paliv\u00e1 – krbov\u00e9 teles\u00e1.
    \nNapr\u00edklad ke\u010f je mal\u00e1 \u00fa\u010dinn\u00e1 v\u00fd\u0161ka a pr\u00e1ve 45\u00b0uhol napojenia m\u00e1 men\u0161\u00ed odpor, a teda n\u00e1beh tepl\u00f4t a t\u00fdm aj spotrebi\u010dom po\u017eadovan\u00fd \u0165ah kom\u00edna je r\u00fdchlej\u0161ie dosiahnute\u013en\u00fd.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/2″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2016\/07\/spravne-napojenie-spotrebica-e1481119920111.png” image_size=”full” desc=”Spr\u00e1vny sp\u00f4sob za\u00fastenia dymovodu” caption_location=”outside-image” align=”center”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”13. Ako spr\u00e1vne napoji\u0165 dymovod na kom\u00edn Schiedel?”][vc_row_inner][vc_column_inner width=”1\/3″][vc_column_text css=”.vc_custom_1648561933613{margin-bottom: 0px !important;}”]Jednozna\u010dne odpor\u00fa\u010dame napoji\u0165 oce\u013eov\u00fd dymovod “NA” \u0161amot, nie “DO” \u0161amotu. Pred\u00eddete t\u00fdm zbyto\u010dn\u00e9mu znehodnoteniu V\u00e1\u0161ho kom\u00edna. Oce\u013e sa neporovnate\u013ene r\u00fdchlej\u0161ie a viac roz\u0165ahuje ako \u0161amot. Preto nedostato\u010dn\u00fd priestor na dilat\u00e1ciu sp\u00f4sob\u00ed n\u00e1sledn\u00e9 prasknutie \u0161amotov\u00e9ho sop\u00facha.<\/p>\n

    Na realiz\u00e1ciu dopojenia odpor\u00fa\u010dame pou\u017ei\u0165 origin\u00e1lne prechodky.<\/a>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2016\/07\/spravne-napojenie-spotrebica-e1481119920111.png” image_size=”full” title=”Spr\u00e1vny sp\u00f4sob za\u00fastenia dymovodu” caption_location=”outside-image” align=”center”][\/vc_column_inner][vc_column_inner width=”1\/3″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2019\/10\/moznosti-schiedel-napojeni-a-redukcii-prechodky-102019.png” image_size=”full” title=”Prechodky a redukcie” caption_location=”outside-image” align=”center”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”14. Kedy musia by\u0165 na kom\u00edne \u010fal\u0161ie dvierka?”][vc_column_text]Druh\u00e9 dvierka – \u010distiaci a kontroln\u00fd otvor – musia by\u0165 realizovan\u00e9 v pr\u00edpade, \u017ee vzdialenos\u0165 medzi \u010distiacimi otvormi je v\u00e4\u010d\u0161ia ako 6 m, pri\u010dom za \u010distiaci otvor sa pova\u017euje aj \u00fastie kom\u00edna, ak je k nemu zodpovedaj\u00faci pr\u00edstup (v\u00fdlez na strechu, stupne na stre\u0161nej krytine, kom\u00ednov\u00e1 lavi\u010dka).[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab title=”15. Ako \u010faleko od kom\u00edna mus\u00ed by\u0165 dreven\u00e1 kon\u0161trukcia krovu, strechy?”][vc_row_inner][vc_column_inner][vc_column_text css=”.vc_custom_1629811551438{margin-bottom: 0px !important;}”]Pri na\u0161ich keramick\u00fdch kom\u00ednoch , na tuh\u00e9 paliv\u00e1, je bezpe\u010dn\u00e1 vzdialenos\u0165<\/strong> 50 mm. R\u00f4zne odstupov\u00e9 vzdialenosti s\u00fa po\u017eadovan\u00e9 pri kovov\u00fdch kom\u00ednoch<\/strong> z nehrdzavej\u00facej ocele. Tie z\u00e1visia od sp\u00f4sobu vedenia kom\u00ednov\u00e9ho telesa<\/strong> v bl\u00edzkosti hor\u013eav\u00fdch \u010dast\u00ed stavby. Odpor\u00fa\u010dame tak\u00fd kom\u00edn konzultova\u0165 s na\u0161imi \u0161pecialistami na kovov\u00e9 kom\u00edny.<\/strong><\/p>\n

    P.S.: Nie je v\u00f4bec d\u00f4le\u017eit\u00e1 prev\u00e1dzkov\u00e1 teplota a spotrebi\u010da a n\u00e1sledne teplota povrchu kom\u00ednov\u00e9ho telesa za be\u017enej prev\u00e1dzky, ale teplota na povrchu kom\u00edna pri vyhoren\u00ed sadz\u00ed. Vtedy je teplota na povrchu kovov\u00e9ho kom\u00edna m\u00f4\u017ee dosiahnu\u0165 a\u017e 300\u00b0C! To je u\u017e z\u00e1paln\u00e1 teplota v\u00e4\u010d\u0161iny materi\u00e1lov vyskytuj\u00facich sa na stavbe.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=”1\/2″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/08\/odstupy-absolut.jpg” image_size=”full”][\/vc_column_inner][vc_column_inner width=”1\/2″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2021\/08\/odstupy-ics-permeter.jpg” image_size=”full”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”16. Mus\u00ed ma\u0165 kom\u00edn hore strie\u0161ku aby do neho nepr\u0161alo?”][vc_row_inner][vc_column_inner width=”2\/3″][vc_column_text]Ak napoj\u00edte najspodnej\u0161iu \u010das\u0165 kom\u00edna na kanaliz\u00e1ciu tak ani nie. Vlhkos\u0165, ktor\u00e1 ste\u010die dole do p\u00e4ty kom\u00edna je odveden\u00e1 mimo kom\u00edn. Ak napojenie nem\u00e1te realizovan\u00e9, pou\u017eite Meidingerovu hlavu<\/strong> alebo Napoleonovu strie\u0161ku<\/strong>, oboje m\u00e1me v ponuke. Av\u0161ak tieto prvky , mno\u017estvo prenikaj\u00facej vlhkosti obmedzuj\u00fa, nezabr\u00e1nia \u00faplne jej prieniku do kom\u00edna.<\/strong>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][mk_image src=”https:\/\/www.schiedel.com\/sk\/wp-content\/uploads\/sites\/13\/2019\/08\/dsc08759.jpg” image_size=”full” svg=”true” lightbox=”true” align=”center”][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=”17. Ako upravi\u0165 kom\u00edn nad strechou?”][vc_column_text]Na\u0161e kom\u00ednov\u00e9 teles\u00e1 odpor\u00fa\u010dame v ochladzovanej \u010dasti zatepli\u0165<\/strong> miner\u00e1lnou vlnou, nie polystyr\u00e9nom. Hr\u00fabka vrstvy zateplenia je uva\u017eovan\u00e1 50 mm<\/strong>, na t\u00fato hr\u00fabku je usp\u00f4soben\u00e1 aj krycia doska na kom\u00ednovom telese.[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab title=”18. D\u00e1 sa kom\u00edn pred\u013a\u017ei\u0165?”][vc_column_text]Ak je probl\u00e9m so spotrebi\u010dom, \u017ee po\u017eaduje vy\u0161\u0161\u00ed kom\u00ednov\u00fd \u0165ah pre svoju prev\u00e1dzku, tak m\u00f4\u017eete pou\u017ei\u0165 na \u00a0pred\u013a\u017eenie kom\u00edna kom\u00ednov\u00e9 n\u00e1stavce fy Schiedel. Trojvrstvov\u00e9 varianty kom\u00ednov\u00fdch n\u00e1stavcov m\u00e1me v ponuke pre v\u0161etky keramick\u00e9 kom\u00ednov\u00e9 syst\u00e9my.[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab title=”19. Naj\u010dastej\u0161ia chyba ?”][vc_row_inner][vc_column_inner width=”1\/2″][vc_column_text]\n