{"id":16111,"date":"2021-07-27T17:31:31","date_gmt":"2021-07-27T15:31:31","guid":{"rendered":"https:\/\/www.schiedel.com\/uk\/?page_id=16111"},"modified":"2023-04-26T16:51:03","modified_gmt":"2023-04-26T14:51:03","slug":"ics-5000-flue-system","status":"publish","type":"page","link":"https:\/\/www.schiedel.com\/uk\/ics-5000-flue-system\/","title":{"rendered":"ICS 5000 flue system"},"content":{"rendered":"
Schiedel is the first European chimney manufacturer to have performed the tests according to this latest fire resistance standard for chimneys.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/6″][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row id=”features”][vc_column][vc_column_text css=”.vc_custom_1627400944357{margin-bottom: 0px !important;}”]\n<\/a> ICS 5000 is a multi-functional twin wall insulated venting system, which is suitable for internal and external use on a wide range of engineering, combustion and process equipment, including heating appliances, diesel generators, CHP systems and service ducting.<\/p>\n ICS 5000 comes with a high quality specification as standard with a 316L Grade Stainless steel liner, high performance mineral blanket insulation and a bright annealed 304 Grade stainless steel outer case.<\/p>\n Both liner and outer case have a continuous seam welded joint and each flue gas bearing component has a uniquely profiled spigot and socket joint with bevelled end forms to ensure ease of installation whilst ensuring the joint meets H1 performance criteria at 5000 Pa.<\/p>\n The thermal insulation blanket ensures continuous insulation over the entire effective length of the liner, ensuring fast priming to normal operating temperatures, whilst maintaining low external surface temperatures.[\/vc_column_text][vc_row_inner][vc_column_inner width=”1\/2″][vc_column_text css=”.vc_custom_1627400959892{margin-bottom: 0px !important;}”]\n<\/a> All BIM and AEC CAD formats, like Autodesk Revit, Nemetschek Allpan and Grafisoft Archicad for the respective CAD systems are available to engineers, planners and purchasers for free. You can add these formats under your own account section. Schiedel BIM is free to use and you just need to enter your email address to register and download your formats (for free!).[\/vc_column_text][\/vc_column][vc_column width=”1\/3″][vc_single_image image=”10350″ img_size=”full” onclick=”custom_link” img_link_target=”_blank” link=”https:\/\/schiedel.partcommunity.com\/3d-cad-models\/stainless-steel-system-schiedel\/?info=schiedel%2Fedelstahlsysteme”][vc_column_text css=”.vc_custom_1643212821876{margin-top: 0px !important;margin-bottom: 0px !important;border-top-width: 0px !important;border-bottom-width: 0px !important;padding-top: 0px !important;padding-bottom: 0px !important;}”]\n <\/p>\n <\/p>\n <\/p>\n <\/p>\nPRODUCT DESCRIPTION<\/h3>\n
PRODUCT FEATURES<\/h3>\n
\n
Schiedel BIM Catalogue<\/h1>\n[\/vc_column_text][vc_column_text css=”.vc_custom_1647591619378{margin-bottom: 0px !important;}”]\n
A range of Schiedel Products for Commercial and Residential are now available within our new 3D BIM (Building Information Modelling) Catalogue.<\/h4>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=”2\/3″][vc_column_text css=”.vc_custom_1647591952531{margin-bottom: 0px !important;}”]Engineers, planners and architects now can have an significant influence on making Schiedel the choice of the chimney at the beginning of the planning process, with the comprehensive data available for a range of components.<\/p>\n
Click to view our BIM catalogue<\/a><\/h4>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row id=”technical-specification”][vc_column][vc_column_text disable_pattern=”false”]\n<\/a>
TECHNICAL SPECIFICATION<\/h3>\n[\/vc_column_text][mk_table]\n
\n\n
\n Fuel<\/td>\n Diesel generators, gas, oil<\/td>\n<\/tr>\n \n Firing temp<\/td>\n 600\u00b0C<\/td>\n<\/tr>\n \n Continuous Firing temp<\/td>\n 600\u00b0 C<\/td>\n<\/tr>\n \n Short Firing temp<\/td>\n 700\u00b0C<\/td>\n<\/tr>\n \n Thermal Shock<\/td>\n 1000\u00b0C<\/td>\n<\/tr>\n \n Mode of Operation<\/td>\n High Positive Pressure 5000 Pa (H1)<\/td>\n<\/tr>\n \n Pressure Capabilities<\/td>\n 5000Pa<\/td>\n<\/tr>\n \n Fire Rating<\/td>\n 4 Hours Fire Rating to BS 476 Part 20<\/td>\n<\/tr>\n \n Outer Case<\/td>\n 304 : 1.4301 : X5CrNi 18-10<\/td>\n<\/tr>\n \n Outer Case Thickness<\/td>\n 0,5mm (\u00d8130-\u00d8300), 0,6mm (\u00d8350-\u00d8600), 0,7mm \u00d8650-\u00d8700)<\/td>\n <\/td>\n<\/tr>\n \n Seam<\/td>\n Fully seam welded<\/td>\n<\/tr>\n \n Liner<\/td>\n 316L : 1.4404 : X2CrNiMo 17-12-2<\/td>\n<\/tr>\n \n Liner Thickness (mm)<\/td>\n 0,5mm (\u00d880 -350), 0,6mm (\u00d8400-\u00d8600)<\/td>\n <\/td>\n<\/tr>\n \n Insulation<\/td>\n High performance mineral fibre<\/td>\n<\/tr>\n \n Insulation Thickness<\/td>\n 25mm or 50mm<\/td>\n <\/td>\n<\/tr>\n \n Average Thermal Resistance (200\u00b0C)<\/td>\n 25mm 0.4 m2k\/W, 50mm 0.6 m2k\/W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/mk_table][\/vc_column][\/vc_row][vc_row id=”applications”][vc_column][vc_column_text css=”.vc_custom_1627397101643{margin-bottom: 0px !important;}”]\n<\/a> CORROSION RESISTANCE<\/h3>\n[\/vc_column_text][vc_column_text css=”.vc_custom_1627397128892{margin-bottom: 0px !important;}”]Chimneys are subject to significant corrosion attack by flue gas condensates, particularly from solid fuel and condensing appliances. ICS is specifically designed and manufactured to resist this\u00a0 corrosion. It is the only stainless steel chimney system in the world to have passed the internationally recognised Gastec corrosion test.[\/vc_column_text][\/vc_column][\/vc_row][vc_row id=”applications”][vc_column][vc_column_text css=”.vc_custom_1627397181196{margin-bottom: 0px !important;}”]\n<\/a>
CHIMNEY DIAMETER<\/h3>\n[\/vc_column_text][vc_column_text css=”.vc_custom_1627397170703{margin-bottom: 0px !important;}”]The chimney size should be as recommended by the appliance manufacturer. Where there is a requirement for a flue diameter smaller than the appliance spigot, then the operational requirements of the appliance and the configuration of the flue must satisfy the flue sizing requirements of BS EN 13384-1 for single appliances.[\/vc_column_text][vc_row_inner][vc_column_inner][vc_column_text css=”.vc_custom_1627401211728{margin-bottom: 0px !important;}”]\n
\n\n
\n System Chimney BS EN 1856-1 (T\u00dcV 0036 CPR 9195 027)<\/td>\n<\/tr>\n \n ICS25 5000<\/td>\n ICS50 5000<\/td>\n<\/tr>\n \n T600 H1 D V3 L50050 O75*<\/td>\n T600 H1 D V3 L50050 O25*<\/td>\n<\/tr>\n \n T200 H1 W V2 L50050 O50**<\/td>\n <\/td>\n<\/tr>\n \n *Distance to Combustibles<\/td>\n *Distance to Combustibles<\/td>\n<\/tr>\n \n *\u00d880-\u00d8300 distance – 75mm<\/td>\n *\u00d880-\u00d8300 distance – 25mm<\/td>\n<\/tr>\n \n *\u00d8350-\u00d8450 distance – 112.5mm<\/td>\n *\u00d8350-\u00d8450 distance – 37.5mm<\/td>\n<\/tr>\n \n *\u00d8500- \u00d8600 distance – 150mm<\/td>\n *\u00d8500- \u00d8600 distance – 50mm<\/td>\n<\/tr>\n \n **\u00d880-\u00d8200 distance – 50mm<\/td>\n <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n\n
\n Connecting Flue Pipe BS EN 1856-2 (T\u00dcV 0036 CPR 9195 038)<\/td>\n Connecting Flue Pipe BS EN 1856-2 (T\u00dcV 0036 CPR 9195 036)<\/td>\n<\/tr>\n \n T600 H1 D V3 L50050 O100 M<\/td>\n T600 H1 D V3 L50050 O100 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n\n
\n EI 120 Fire rating to BS EN 1366-13 Chimneys<\/td>\n<\/tr>\n \n ICS25 5000<\/td>\n ICS50 5000<\/td>\n<\/tr>\n \n Horiziontal and Vertical<\/td>\n Horiziontal and Vertical<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n\n
\n BS 476 part 20 (4 Hour Fire Rating)<\/td>\n<\/tr>\n \n ICS25 5000<\/td>\n ICS50 5000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n\n
\n Corrosion testing on Gas, Oil, Solid Fuel (T\u00dcV 0036 CPR 9195 027)<\/td>\n<\/tr>\n \n Gastec, MPA,T\u00dcV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][mk_divider style=”thin_solid” margin_top=”0″][\/vc_column][\/vc_row][vc_row id=”downloads”][vc_column][vc_column_text disable_pattern=”false” css=”.vc_custom_1682520660977{margin-bottom: 0px !important;}”]\n<\/a> DOWNLOADS<\/h3>\n