{"id":16907,"date":"2022-05-30T13:49:57","date_gmt":"2022-05-30T11:49:57","guid":{"rendered":"https:\/\/www.schiedel.com\/ie\/?page_id=16907"},"modified":"2022-08-23T15:18:03","modified_gmt":"2022-08-23T13:18:03","slug":"the-fine-pm-2-5-dust-filter-for-wood-burning-stoves-epuro","status":"publish","type":"page","link":"https:\/\/www.schiedel.com\/ie\/the-fine-pm-2-5-dust-filter-for-wood-burning-stoves-epuro\/","title":{"rendered":"The fine pm 2.5 dust filter for wood burning stoves – ePuro"},"content":{"rendered":"
[vc_row fullwidth=”true”][vc_column width=”1\/2″][vc_column_text css=”.vc_custom_1653904815570{margin-bottom: 0px !important;}”]\n

Schiedel ePURO<\/h1>\n

The fine dust filter for wood burning stoves<\/h4>\n

ePURO is an electrostatic fine dust separator for effectively reducing flue gas particles in wood burning appliances in existing buildings, drastically reducing PM 2.5 particles by up to 95%<\/p>\n

As a renewable resource, wood releases only as much carbon dioxide (CO2) when burning, the same as with the natural decomposition process in the forest, or as much as the tree has stored during its growth process. Wood does not release any additional CO2 when burning.[\/vc_column_text][\/vc_column][vc_column width=”1\/2″][mk_image src=”https:\/\/www.schiedel.com\/uk\/wp-content\/uploads\/sites\/12\/2022\/05\/epuro-main-image.jpg”][\/vc_column][\/vc_row][vc_row][vc_column][mk_ornamental_title tag_name=”h4″ text_color=”#a3c100″ font_family=”none” font_size=”29″ font_weight=”500″ ornament_style=”norman-short-single” nss_align=”center”]\n

UP TO 95% PARTICLE REDUCTION<\/p>\n[\/mk_ornamental_title][\/vc_column][\/vc_row][vc_row][vc_column width=”1\/2″][vc_column_text css=”.vc_custom_1653637359106{margin-bottom: 0px !important;}”]\n<\/a>

Electrostatic technology = particle reduction<\/h3>\n

The Schiedel ePURO fine dust filter is an electrostatic particle separator for wood burning appliances, such as wood burning stoves, but also for wood\/pellet central heating systems, up to 50 kW.<\/p>\n

The installation is relatively simple from the start. A 230 V connection needs to be provided on site.<\/p>\n

The adaptability of Schiedel ePURO makes it possible to use it on existing steel chimneys. It reduces the fine dust content in the flue gas by up to 95%, which contributes to cleaner air.<\/p>\n

Taking local emission regulations into consideration, new and existing stoves can be equipped with the Schiedel ePURO.[\/vc_column_text][mk_table]\n\n\n\n\n\n\n\n\n\n\n\n
Technical specifications<\/td>\n<\/tr>\n
High voltage<\/td>\n15 to 30 kV (modulating)<\/td>\n<\/tr>\n
electrical power<\/td>\nmax. 30 W<\/td>\n<\/tr>\n
Standby operation<\/td>\n0.7 W<\/td>\n<\/tr>\n
Diameter of the application area<\/td>\n<\/tr>\n
Ceramic<\/td>\n\u00d8 16, 18, 20 cm<\/td>\n<\/tr>\n
Stainless steel<\/td>\nIndividually adjustable<\/td>\n<\/tr>\n
Approval<\/td>\n<\/tr>\n
DIBT-approval Z-7.4-3451<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/mk_table][\/vc_column][vc_column width=”1\/2″][vc_single_image image=”16918″ img_size=”full”][\/vc_column][\/vc_row][vc_row][vc_column][vc_custom_heading text=”Click here to register for our webinars” font_container=”tag:h4|font_size:29|text_align:center|color:%23a3c100″ use_theme_fonts=”yes” css_animation=”slideInLeft” link=”url:https%3A%2F%2Fwww.schiedel.com%2Fie%2Fthe-fine-pm-2-5-dust-filter-for-wood-burning-stoves-epuro%23contact”][\/vc_column][\/vc_row][vc_row][vc_column width=”1\/2″][vc_column_text css=”.vc_custom_1653646101615{margin-bottom: 0px !important;}”]\n<\/a>

How it works<\/h3>\n

The active fine dust filter with electrostatic separation charges the dust particles contained in the flue gas. This causes them to deposit on the inner wall of the steel chimney.<\/p>\n

Cleaning is carried out without dismantling the separator, when the chimney is swept.<\/p>\n

The system is activated when the connected fireplace is in operation. The 230 V high-voltage transformer delivers power of 15 to 30 kV with max. 30\u00a0W. In stand-by mode, the consumption is\u00a0a\u00a0low 0.7 W.[\/vc_column_text][\/vc_column][vc_column width=”1\/2″][vc_single_image image=”16917″ img_size=”full”][\/vc_column][\/vc_row][vc_row equal_columns=”true” el_class=”row-height”][vc_column width=”1\/4″][vc_single_image image=”16916″ img_size=”full” alignment=”center”][vc_column_text css=”.vc_custom_1653033178063{margin-bottom: 0px !important;}”]1.The fine dust particles in the flue gas flow through the chimney flue.[\/vc_column_text][\/vc_column][vc_column width=”1\/4″][vc_single_image image=”16915″ img_size=”full” alignment=”center”][vc_column_text css=”.vc_custom_1653033237386{margin-bottom: 0px !important;}”]2. Electrons are released by means of a high voltage electrode.[\/vc_column_text][\/vc_column][vc_column width=”1\/4″][vc_single_image image=”16914″ img_size=”full” alignment=”center”][vc_column_text css=”.vc_custom_1653033245617{margin-bottom: 0px !important;}”]3. The electrostatically charged particles move to the chimney’s inner wall.[\/vc_column_text][\/vc_column][vc_column width=”1\/4″][vc_single_image image=”16913″ img_size=”full” alignment=”center”][vc_column_text css=”.vc_custom_1653033251912{margin-bottom: 0px !important;}”]4. The fine dust collects on the inner wall of the chimney.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text css=”.vc_custom_1653036413517{margin-bottom: 0px !important;}”]\n<\/a>

Components<\/h3>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=”1\/2″][mk_table]\n\n\n\n\n\n\n\n\n\n\n\n\n\n
COMPONENT<\/td>\nSAP<\/td>\nSCHEMATIC COMPONENT<\/td>\nDIAMETER<\/td>\n<\/tr>\n
Filter<\/td>\n175680<\/td>\n1-7b<\/td>\nall<\/td>\n<\/tr>\n
Adapter<\/td>\natyp<\/td>\n–<\/td>\non demand<\/td>\n<\/tr>\n
T – Piece<\/td>\n161773<\/td>\n8<\/td>\n<150<\/td>\n<\/tr>\n
161775<\/td>\n8<\/td>\n<200<\/td>\n<\/tr>\n
161777<\/td>\n8<\/td>\n<300<\/td>\n<\/tr>\n
Reduction tube (L500)<\/td>\n160904<\/td>\n9<\/td>\n130<\/td>\n<\/tr>\n
Locking band<\/td>\n161293<\/td>\n8 to 9<\/td>\n130<\/td>\n<\/tr>\n
161294<\/td>\nadapter to 8<\/td>\n150<\/td>\n<\/tr>\n
161296<\/td>\nadapter to 8<\/td>\n200<\/td>\n<\/tr>\n
161298<\/td>\nadapter to 8<\/td>\n300<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/mk_table][mk_table]\n\n\n\n\n\n\n\n
OPT. EXTRAS<\/td>\nSAP<\/td>\nSCHEMATIC COMPONENT<\/td>\nLENGTH<\/td>\n<\/tr>\n
Safety switch<\/td>\n176054<\/td>\n–<\/td>\n–<\/td>\n<\/tr>\n
Longer connection cable<\/td>\n176055<\/td>\n5<\/td>\n5m<\/td>\n<\/tr>\n
176056<\/td>\n5<\/td>\n10m<\/td>\n<\/tr>\n
LCD display<\/td>\n176057<\/td>\n–<\/td>\n–<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/mk_table][\/vc_column][vc_column width=”1\/2″][vc_single_image image=”16912″ img_size=”full”][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text css=”.vc_custom_1653036651352{margin-bottom: 0px !important;}”]\n<\/a>

Installation example<\/h3>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=”1\/3″][vc_single_image image=”16911″ img_size=”full”][\/vc_column][vc_column width=”1\/3″][vc_single_image image=”16910″ img_size=”full”][\/vc_column][vc_column width=”1\/3″][vc_single_image image=”16909″ img_size=”full”][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text css=”.vc_custom_1653036574193{margin-bottom: 0px !important;}”]\n<\/a>

Environmental. CO2 neutral. Sustainable.<\/h3>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=”5\/6″][vc_column_text css=”.vc_custom_1653637427762{margin-bottom: 0px !important;}”]Climate protection concerns all of us. The intelligent and sustainable use of sustainable raw materials, such as wood, as a renewable energy source, combined with energy efficiency heating systems helps to meet climate protection requirements and makes a significant contribution to lowering emissions.<\/p>\n

As a renewable resource, wood releases only as much carbon dioxide (CO2) when burning, the same as with the natural decomposition process in the forest, or as much as the tree has stored during its growth process. Wood does not release any additional CO2 when burning.<\/p>\n

Air pollution has a tremendous impact on our health and our environment. Compared to other energy sources, firewood has a low emission factor with a very low primary energy factor of 0.2.<\/p>\n

Even though wood is a low cost and above all sustainable alternative to the current excessive gas and oil costs, wood is also criticised due to the fine dust discussion. Outdated stoves with obsolete combustion technology are\u00a0a decisive factor here.<\/p>\n

Modern stoves with efficient burning technologies do not contribute to an excessive fine dust load when used correctly. – Briefly put: Old appliances are part of the problem. New appliances are part of the solution.[\/vc_column_text][\/vc_column][vc_column width=”1\/6″][vc_single_image image=”14906″ img_size=”full”][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text css=”.vc_custom_1653911809513{margin-bottom: 0px !important;}”]

\r\n
\r\n
\r\n
\r\n \r\n ePuro brochure\r\n <\/a>\r\n
\r\n

ePuro brochure<\/h4>\r\n\r\n
<\/i> 1.32 MB<\/div>\r\n <\/div>\r\n<\/div>\r\n<\/div>\r\n
Download<\/a><\/div>
<\/div><\/div>\r\n<\/div>\r\n<\/div>\r\n